VEIRA Mastering Analyzer

What is VEIRA Mastering Analyzer for?

It’s a meter for finished mixes and masters. It shows, in one rack-unit window, how loud the master is against the target of where it’s going (a streaming service, a broadcaster, a platform), its true peak and dynamics, its spectrum and spectrogram, and its tonal balance, dynamics and width compared with reference songs you choose. It changes nothing in the sound and adds no latency, so put it last on the master bus, after the limiter.

How is it different from VEIRA Metering Suite?

It shares the Metering Suite’s loudness engine, its 19 loudness targets and its loudness, history, level and stereo displays. It adds, for mastering: the rack-unit panel with eight screens at once, a spectrogram, the tonal balance against targets you learn from your own reference songs, and dynamics, correlation and width in five bands. The Metering Suite remains the compact meter for mixing and delivery, with its VU needles.

How do I make a tonal target?

Route a reference song you love through the analyzer, press RESET and play it (a whole song is best; at least 10 seconds are needed). Press NEW TARGET and name it: the programme measured since the reset becomes the target and is saved as a file. For a steadier target, press RESET, play the next reference and press ADD SONG; three to five songs make a good target. Then press RESET and play your own master: TONAL BALANCE and BANDS compare it with the target.

How do I read TONAL BALANCE?

With a tonal target, 0 dB is the references’ average in each third octave and the green range is their spread (10th to 90th percentile). The amber line is your master’s average since the reset, and the light line the last 3 seconds. Where the amber line runs above the green, your master has more there than your references; below it, less; inside it, it’s within their own variation. Because everything is relative to the loudness, a loud master and a quiet reference compare directly.

What does DYNAMICS in BANDS show?

The crest factor of each band, its sample peak over its RMS level, over the last 3 seconds, in dB. A band with lively transients reads high; a heavily compressed or limited one reads low (a steady sine is 3 dB, the lowest possible). The tick marks your master’s average, and with a tonal target the green range shows your references’ crest factors in that band: well below it, that band is more squashed than the music you chose; well above, more dynamic.

NEW TARGET says there isn’t enough to capture yet. Why?

The analyzer needs at least 10 seconds of programme measured since the last RESET, counted while the music is within 20 LU of its loudest moment, so silences and fades don’t count. Play more of the reference (a whole song is best) and press it again. If the transport is stopped with HOLD ON STOP on, nothing is being counted: press play.

Does it change the sound or add latency?

No. The output is the input, bit for bit, with no latency, at any buffer size. That’s why it belongs last on the master bus, after your limiter, where it measures exactly what you deliver. Offline bounces are always measured, so you can also bounce with the analyzer on the master to measure the exact file.

VEIRA Mastering Analyzer · Help · VEIRA